Set up the storm and the city
Storm presets
The storm
The city (100 hectares, 20,000 people)
Roofs, roads and parking lots shed water instead of soaking it in.
Share of paved area drained to rain gardens, green roofs or permeable pavement.
The sewer system
How much flow the pipe to the treatment plant can carry, as a multiple of normal dry-weather sewage flow.
An Olympic pool holds about 2,500 m³.
The river
Low in a dry summer, high after spring snowmelt.
What happened in 24 hours
Peak stormwater runoff
0m³/s
Overflow to river
0m³
Overflow duration
0h
Wastewater treated
0%
Peak river E. coli
0CFU/100 mL
Swimming closed
0h
Flow in the sewer system: where it comes from and where it goes
Sewage from homes
Stormwater from drains
Combined sewer flow
Sent to treatment plant
Overflow to river
Interceptor capacity
Raining
E. coli in the river below the outfall (log scale)
River E. coli
Swim advisory level, 235 CFU/100 mL
Worksheet
Follow-along slideshow · 41 slides: real sewer overflows from Washington to London, Learn It slides for each part, and the worksheet question by question
Printable student worksheet (PDF) · two pages, 14 questions: one pipe with two jobs, storms and streets, three ways to fix the sewer, and what reaches the river
Low-write worksheet (PDF) · same questions with tick boxes, word banks and worked examples
Teacher guide: NYSSLS, SEP and CCC alignment (PDF)
How the model works, and where it simplifies
- Time is not shown at a steady rate. The animation slows down while it rains, runs faster while the sewer is still overflowing, and goes fastest in dry weather. Use the time slider to read exact hours.
- Dots with white outlines show water moving from one pipe or tank to the next. More dots moving faster means more flow. Brown dots are mostly sewage and blue dots are mostly stormwater. The dots show which way the water goes, not its actual speed.
- Homes send sewage around the clock. Use is lowest in the early morning and highest in the afternoon. Storm drains only carry water during rain and for a little while afterwards.
- Runoff uses the rational method, Q = C·i·A, with C = 0.90 for paved surfaces, 0.25 for paved areas drained to green infrastructure and 0.15 for lawns and soil. A 20-minute delay smooths the flow as it travels through streets and pipes.
- Sewage: 20,000 people × 300 L per person per day, about 0.07 m³/s, rising and falling a little through the day. The regulator sends flow up to the interceptor's capacity to the plant. Extra flow fills the tank first and then spills over the weir to the river. The tank empties to the plant once there is spare capacity.
- E. coli: about 5 million CFU/100 mL in raw sewage, 10,000 in urban stormwater and 50 upstream. The 1 km reach below the outfall (60,000 m³) is treated as well mixed, and bacteria die off at 0.8 per day. 235 CFU/100 mL is a common single-sample beach advisory level in the United States.
- The model leaves out soil getting wetter during a storm, pipe travel times, the "first flush" of dirt at the start of a storm, tides and river currents that carry pollution further downstream. All values are realistic, but they describe a made-up city, not a real one.